Single Phase Automatic Changeover | automatic changeover switch

Single Phase Automatic Changeover Switch for Generator:

This Diagram Shows A Pressure Switch With The “Change-Over” Switching Function Represents a Special Version of a Pressure Switch With Two Switching Outputs Acting Oppositely to Switch Two Circuits. A “Change-Over” Closes One Circuit And Simultaneously Opens a Second Circuit. A Changeover Switch is Designed to Transfer a House's Electricity from the Commercial Power Grid to a local Generator When an Outage Occurs.

Diagram of Single Phase Automatic Changeover Switch wiring:

Single Phase Automatic Changeover Switch for Generator
Fig 1: Single Phase Automatic Changeover Switch for Generator


Components Need for this Project:

You can get the components from any of the sites below:

  1. Single Phase Energy Meter [See Buy Click Amazon]
  2. DP MCB [See Buy Click Amazon]
  3. Magnetic Contactor [See Buy Click Amazon]
  4. Generator [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Read Also:

Components used to make the Single Phase Automatic Changeover Switch :

01. Single Phase Energy Meter

Single Phase Energy Meter
Fig 2: Single Phase Energy Meter
The measuring device with the help of which the electric power or energy of a circuit is measured is called Energy Meter (Energy Meter). Also called a watt-hour or kilowatt-hour meter. For home appliances, we used a single-phase energy meter. The single-phase energy meter is directly connected between the line and the load. Both coils produce their magnetic fields, when the meter is connected to the supply line, and the load. Energy meters are used in homes and in industrial applications where we want to found that how much energy is being consumed by home appliances and electrical equipment.


02. DP MCB

DP MCB
Fig 3: DP MCB
Double pole MCB can control two wires. This circuit breaker is generally used in single-phase electric lines. Double pole MCB circuit breaker input has two wires supply two wires and an output. In a single-phase line, A double-pole MCB circuit breaker is used to give good production. This circuit breaker is provided through phase and neutral circuit breaker, it is very safe. This circuit breaker is preferred for home appliances. A DP MCB usually trips for 2 reasons 1. Overload 2. Short circuit.


03. Magnetic Contactor

Magnetic Contactor
Fig 4:  Magnetic Contactor
A magnetic contactor is an electrical device used for load control, automation, and protection. It is much like a magnetic reel. However, relays are generally used for low power and voltage, on the other hand, when we think of high power, these heavy-duty contractors only come to mind. It basically works by switching the load on and off. It has 3 terminals whose inputs are denoted as L1, L2, L3, and outputs as T1, T2, and T3. The circuit of the load is made in automation mode or protection using auxiliary contacts. It has two types of terminals. 1) Normally Open (NO). 2) Normally Closed (NC)

04: Generator

Generator
Fig 5: Generator
The Power Generator Is a Device That Converts Motive Power (Mechanical Energy) or Fuel-Based Power (Chemical Energy) Into Electric Power for Use in an External Circuit. In Addition to Electromechanical Designs, Photo Voltaic, And Fuel Cell-Powered Generators Utilize Solar Power and Hydrogen-Based Fuels, Respectively, to Generate Electrical Output. The Reverse Conversion of Electrical Energy Into Mechanical Energy is Done by an Electric Motor, And Motors, And Generators Have Many Similarities. Many Motors can be Mechanically Driven to Generate Electricity; Frequently They Make Acceptable Manual Generators.