3-Phase Motor with Single Phase Supply | 3-Phase Motor to Single Phase

Three Phase Motor with Single Phase Supply:

This circuit diagram shows how to connect three phase motor with single-phase wiring. In this circuit diagram, we use a single-phase energy meter, a DP MCB ( Double Pole Miniature Circuit Breaker ), a magnetic contactor, an NO ( Normal Open ) switch, NC ( Normal Close ) switch, a capacitor, and a single-phase motor. This diagram is very simple and easy to connect. If you want to connect this diagram like this image please check our youtube video.

Diagram of 3-Phase Motor on Single Phase wiring:

3 Phase Motor with Single Phase Supply
Fig 1: 3 Phase Motor with Single Phase Supply

Components Need for this Project:

You can get the components from any of the sites below:

  1. Single Phase Energy Meter [See Buy Click Amazon]
  2. DP MCB [See Buy Click Amazon]
  3. Magnetic Contactor [See Buy Click Amazon]
  4. NO Switch [See Buy Click Amazon]
  5. NC Switch [See Buy Click Amazon]
  6. Single Phase Motor [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Read Also:

Components used to make the 3-Phase Motor with Single Phase Supply :

01. Single Phase Energy Meter

Single Phase Energy Meter
Fig 2: Single Phase Energy Meter
The measuring device with the help of which the electric power or energy of a circuit is measured is called Energy Meter (Energy Meter). Also called a watt-hour or kilowatt-hour meter. For home appliances, we used a single-phase energy meter. The single-phase energy meter is directly connected between the line and the load. Both coils produce their magnetic fields, when the meter is connected to the supply line, and the load. Energy meters are used in homes and in industrial applications where we want to found that how much energy is being consumed by home appliances and electrical equipment.


02. DP MCB

DP MCB
Fig 3: DP MCB
Double pole MCB can control two wires. This circuit breaker is generally used in single-phase electric lines. Double pole MCB circuit breaker input has two wires supply two wires and an output. In a single-phase line, A double-pole MCB circuit breaker is used to give good production. This circuit breaker is provided through phase and neutral circuit breaker, it is very safe. This circuit breaker is preferred for home appliances. A DP MCB usually trips for 2 reasons 1. Overload 2. Short circuit.


03. Magnetic Contactor

Magnetic Contactor
Fig 4: Magnetic Contactor
A magnetic contactor is an electrical device used for load control, automation, and protection. It is much like a magnetic reel. However, relays are generally used for low power and voltage, on the other hand, when we think of high power, these heavy-duty contractors only come to mind. It basically works by switching the load on and off. It has 3 terminals whose inputs are denoted as L1, L2, L3, and outputs as T1, T2, and T3. The circuit of the load is made in automation mode or protection using auxiliary contacts. It has two types of terminals. 1) Normally Open (NO). 2) Normally Closed (NC).

04. NO Switch

NO Switch
Fig 5: NO Switch
The operator switch has its contact in Normally Open condition. To make Ladder Logic you need to understand NO contact. A Classic Switch has one Input And one Output. In "No Switch," YoungBoy Raps About Ammunition, Murder, Firearms, and Firearm Attachments Such as a Switch. The contact of the switch whose contact is already open is NO. That is enough to understand. no switch in a circuit, then the circuit will not function as intended. to write a program such that when the red light is on, This switch is now in normally open condition. When you push the switch it will close and the red light will turn on.


05. NC Switch

NC Switch
Fig 6: NC Switch
Indicates the contacts of switches or automatic actionable devices. Simply put, the push switches, magnetic contactors, and relays that we use in the factory Normally have Close Contact exists. At this moment the switch will be in normally closed condition. Because already he is sitting close. When turned off the contact will open. To make ladder logic you need to understand NC contact. As already explained. The switch contact is already closed in NC. That is enough to understand.


06. Single Phase Motor

Single Phase Motor
Fig 7: Single Phase Motor
Single-Phase Induction Motor is Very Simple in Construction, Economical, Reliable, and Easy to Repair And Maintain. Due to all these advantages, it is widely used in vacuum cleaners, fans, centrifugal pumps, blowers, washing machines, etc. It can run only by supplying 1 phase current through this motor. The main two parts of this motor are Rotor and Stator. Among them, the rotating part is the Rotor and the stationary part is the Stator. Like all induction motors, a single-phase induction motor consists of two main parts, the stator, and the rotor.