Timer with two contactor wiring

Timer with two contactor wiring:

This diagram shows how to make a timer with two contactor wiring. In this circuit, we use a timer, two magnetic contactors, a DP MCB ( Double Pole Minature Circuit Breaker ), and a selector switch. First, we need to connect the DP MCB with the power source, then connect the magnetic contactor with the power source, then connect the timer with the contactor. Now this circuit is ready for use.

Diagram of Timer with two contactor wiring:

Timer with two contactor wiring
Fig 1: Timer with two contactor wiring

Components Need for this Project:

You can get the components from any of the sites below:

  1. DP MCB [See Buy Click Amazon]
  2. Contactor [See Buy Click Amazon]
  3. Timer [See Buy Click Amazon]
  4. Selector Switch [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Read Also:

Components used to make the Timer with two contactor wiring:

01. DP MCB

DP MCB
Fig 2: DP MCB


Double pole MCB can control two wires. This circuit breaker is generally used in single-phase electric lines. Double pole MCB circuit breaker input has two wires supply two wires and an output. In a single-phase line, A double-pole MCB circuit breaker is used to give good production. This circuit breaker is provided through phase and neutral circuit breaker, it is very safe. This circuit breaker is preferred for home appliances. A DP MCB usually trips for 2 reasons 1. Overload 2. Short circuit.

02. Contactor

Contactor
Fig 3: Contactor


A magnetic contactor is an electrical device used for load control, automation, and protection. It is much like a magnetic reel. However, relays are generally used for low power and voltage, on the other hand, when we think of high power, these heavy-duty contractors only come to mind. It basically works by switching the load on and off. It has 3 terminals whose inputs are denoted as L1, L2, L3, and outputs as T1, T2, and T3. The circuit of the load is made in automation mode or protection using auxiliary contacts. It has two types of terminals. 1) Normally Open (NO). 2) Normally Closed (NC)

03. Timer

Timer
Fig 4: Timer


Timer is a specialized type of clock used for measuring specific time intervals.An electromechanical cam timer uses a small synchronous AC motor turning a cam against a comb of switch contacts. This type of timer often has a friction clutch between the gear train and the cam, the cam can be turned to reset the time.A simple example of the first type is an hourglass. Working method timers have two main groups: hardware and software timers.Most timers give an indication that the time interval that had been set has expired.

04. Selector Switch

Selector Switch
Fig 5: Selector Switch


Selector Switches Can be Rotated left, Right, or in The Center in Order to Open or Close The Electrical Contacts. The Function of a Selector Switch is To Control Devices as well as Switch Between a Minimum of Two or More Circuits. The perfect Use For a Selector Switch is When Used for Controlling an Output of a Device. Selector Switches Come as a Complete Unit Often listed as a Terminal Block Meaning the Selector Switch is a Complete Block Which Makes it Simple And easy to Install.

Thank You for visiting the website. Keep visiting for more Updates.

Post a Comment

Do leave your comments

Previous Post Next Post

Advertisements

Advertisements

Blogging Experiment
Electronic Experiment Subscribe our Youtube Channel
Subscribe