Power Socket wiring diagram:
This diagram shows how to make Power Socket Wiring Diagram. In this circuit, we use two FP MCBs ( Four Pole Minature Circuit Breakers), some DP MCBs ( Double Pole Minature Circuit Breaker ), and a power socket. First, we need to connect the MCB 1 with the power source, then connect the differential switch with the MCB, then connect all MCB circuit breakers and then connect the power socket.
Diagram of Power socket wiring:
Components Need for this Project:
You can get the components from any of the sites below:
- FT MCB [See Buy Click Amazon]
- RCCB [See Buy Click Amazon]
- DP MCB [See Buy Click Amazon]
- Power Socket [See Buy Click Amazon]
Read Also:
Components used to make the 3 phase Socket wiring:
01. FT MCB
![]() |
Fig 2: FT MCB |
Four pole MCCB for Four wires connections, the one additional Four pole for neutral wire connection so that between neutral and any of the other three will supply. It is used where is the possibility of a high neutral current (due to unbalanced loads and /or Third and multiple Third harmonics current etc) and Neutral / Earth Protection is provided on Neutral. Four Pole Circuit Breakers Have advantages in the case When one of the Poles of the Device will get Damaged, and they also provide Isolation from neutral voltage.
02. RCCB
![]() |
Fig 3: RCCB |
The RCCB (Residual Current Circuit Breaker) or RCCB is an electrical protective device. A residual Current Circuit Breaker is specially designed to protect the electrical circuit against earth faults and humans from electrical shock. In this, under normal conditions the load is always connected between the phase terminal to the neutral terminal, hence the flow of the phase current is equal to the neutral current. Earth fault or fault in a power system can cause excess heating, more power consumption, burning or fire, etc. So, protection against earth leakage is very important.
03. DP MCB
![]() |
Fig 4: DP MCB |
Double pole MCB can control two wires. This circuit breaker is generally used in single-phase electric lines. Double pole MCB circuit breaker input has two wires supply two wires and an output. In a single-phase line, A double-pole MCB circuit breaker is used to give good production. This circuit breaker is provided through phase and neutral circuit breaker, it is very safe. This circuit breaker is preferred for home appliances. A DP MCB usually trips for 2 reasons 1. Overload 2. Short circuit.
04. Power Socket
![]() |
Fig 5: Power Socket |
A socket is a type of equipment used in electrical wiring lines that always has an electrical connection. According to the need, it can be supplied to the electrical equipment. In case of electric iron, electric hand drill machine and electric hand grinder etc. two-pin socket with earth terminal is used. Also, three-pin sockets are used for electrical appliances that have a metal body and are likely to be electrified. Eg – Refrigerator, room heater, table heater, hot-plate, electric oven etc.
Thank You for visiting the website. Keep visiting for more Updates.